5.4 Short overview of all error codes
Error code Type Adjustable in Keypad display Info
0x2310 Fault - OC power mod. CiA: connuous overcurrent (inside the device)
0x2320 Fault - Earth fault error CiA: short circuit/earth fault (inside the device)
0x2340 Fault - OC short circuit CiA: short circuit (inside the device)
0x2350 Fault - OL i2t motor CiA: i²*t overload (thermal state)
0x2382 Error 0x2D40:005
(PAR 135/005)
ixt error I*t error
0x2383
Warning - ixt warning I*t warning
0x2387 Fault - OC11 error Clamp responds too oen
0x3120 Fault - Su02 error Single phase failure
0x3210 Fault - Overvolt. error DC bus overvoltage
0x3211 Warning - W.OV DC bus DC bus overvoltage warning
0x3220 Trouble - Undervolt. error DC bus undervoltage
0x3221 Warning - W.UV DC bus DC bus undervoltage warning
0x3222 Warning - W. switch-on voltage DC-bus voltage too low for switch-on
0x4210 Fault - Overtemp.error1 Overtemp. error power mod.
0x4280 Fault - Heatsink sens. Thermal sensor heatsink error
0x4281 Warning - Heats. fan error Heatsink fan error
0x4285 Warning - W.OT1 Power module overtemperature warning
0x4310 Error 0x2D49:002
(PAR 309/002)
OT motor Motor temperature has reached error threshold
0x5112 Warning - W.24V supply 24 V supply crical
0x6010 Warning - Watchdog reset Watchdog me-out
0x6181 Fault - Time-out 125 us task Time-out in 125 us task
0x6182 Fault - Time-out 250 us task Time-out in 250 us task
0x6183 Fault - Time-out 1 ms task Time-out in 1 ms task
0x6184 Fault - Time-out 8 ms task Time-out in 8 ms task
0x6188 Fault - Error dF12 Internal error
0x6189 Fault - Programming error Power secon programming error
0x618A Warning - Int. fan error Internal fan error
0x6190 Fault - PS COM inapplicable Communicaon protocol version in the power secon inapplicable
0x6191 Trouble - Sync.error PS Communicaon in the power secon not synchronous
0x6192 Trouble - Rx error PS Communicaon recepon error in the power
secon at control unit
0x6193 Fault - rx error power sec. Power secon comm. recepon error
0x6194 Fault - COM SDO abort PS PDO communicaon with power secon aborted
0x6195 Warning - I2C conn. lost I2C connecon lost
0x6196 Warning - I2C bus error I2C bus error
0x61B0 Fault - PS uC supply err. uC supply voltage drop in the power secon
0x61B1 Fault - Err. PS general General error in the power secon
0x6280 Fault - Incorrectly connected Trigger/funcons connected incorrectly
0x6281 Fault - User-def fault 1 User-dened fault 1 iniated via trigger/funcon
0x6282 Fault - User-de
f fault 2 User-dened fault 2 iniated via trigger/funcon
0x6290 Warning - Backw dir.prot. Reversal warning
0x6291 Fault - Fault overow Number of maximum permissible faults exceeded
0x62A0 Fault - AC ctrl user err AC control user error
0x62A1 Fault - User-def fault 1 User-dened fault 1 triggered via network
0x62A2 Fault - User-def fault 2 User-dened fault 2 triggered via network
0x62B1 Fault - NetwordIN1 error NetwordIN1 funcon assignment incorrect
0x63A0 Fault - Eeprom error On-board EEPROM access error
0x63A1 Fault - id tag error CU Loading the ID tag calibraon data in the control unit failed
0x63A2 Fault - ID tag error PS Loading the ID tag calibraon data in the power secon failed
0x63A3 Fault - Error PS31 Power secon unknown
0x63A4 Warning - OBEE T. OVERFL. OBEE mer overow
0x7080 Fault - Error SL Asseron le