5.3.2 Error history buer
For purposes of diagnoscs, the error hist
ory buer contains the last 32 error and warning
messages of the inverter, which have occurred during operaon. The error history buer can
be read out using the keypad via PAR 155 and provides a limited view on the logbook.
Details
•
For each event tha
t is recorded, the error history buer contains the message text, the error
code, the me of occurrence as well as a coun
ter for successive, idencal events. If an event
that has already been recorded occurs repeatedly, only the counter is incremented.
•
The error history buer can be reset by the user. In order to prevent the buer from being
reset by the user, this funcon can be protected by means of a password.
•
Observe that the error history buer only presents a snapshot at the me the data are read
out. If a new event occurs, the error history buer must be read out again via PAR 155 so
that the new event becomes visible.
Accessing the error history buer with the keypad
1.Use the key in the operang mode to naviga
te to the
parameterisaon mode one level below.
You are now in the group level. All parameters of the
inverter are divided into dierent groups according to
their funcon.
Note: Use the
key to navigate one level upwards
again anyme.
2.Use the navigaon key to select group 1 ("Diagnos-
cs").
3.Use the key to navigate to one level below.
You are now in the parameter le
vel of the group selec-
ted.
4.Use the
and navigaon keys to select the PAR 155
parame
ter.
5.Use the
key to navigate to one level below.
You are now in the error histor
y buer.
6.With the
and navigaon keys you can now scroll
through the fault memory entries.
B
y means of the
key, you can switch over the display.
Informaon displayed (page 1):
❶
Message text
❷
Err
or memory entry (01 = most recent event)
❸
Response (W = warning, T = trouble, F = fault)
❹
Error code
Informaon displayed (page 2):
❺
Time of occurrence
❻
Error memory entry (01 = most recent event)
❼
Counter for successive, idencal events
Note: By using the
key you can exit the error history
buer again.
Parameter Name / value range / [default seng] Info
0x2006:000
(PAR 155/000)
Error histor
y buer: Keypad display
(Fault memory: Keypad display)
•
Read only
Display of the error history buer on the keypad.
0x2006:001 Error history buer: Maximum number of messages
•
Read only
Display of the maximum number of messages which can be stored in the
history buer (from subindex 6).
0x2006:002 Error history buer: Latest message
•
Read only
Display of the subindex of the most r
ecent message.
Diagnoscs and fault eliminaon
Diagnoscs
Error history buer
46