7.3.4 Slip compensaon
Slip compensaon serves to automacally compensate for a load-dependent speed loss.
Precondions
In order that the slip compensaon can determine the rated slip correctly, the following
parameters mus
t be set correctly:
•
Rated speed
•
Rated frequency
•
Number of pole pairs (automacally calculated from Rated speed and Rated frequency)
Parameter Name / value range / [default seng] Info
0x2B09:001
(PAR 315/001)
Slip compensaon: Gain
(Slip compens.: Slip: gain)
-200.00 ... [100.00] ... 200.00 %
Adjus
tment in percent of the slip calculated.
•
For instance required for deviaons of the real motor data from the
nameplate data.
•
A seng of 100 % corresponds to the rated slip of the machine in the
nominal operang point.
0x2B09:002
(PAR 315/002)
Slip compensaon: Filter me
(Slip compens.: Filter me)
1 ... [5] ... 6000 ms
0x2C02:004
(PAR 351/004)
Motor paramet
er (ASM): Slip frequency
(ASM motor par.: ASM slip freq.)
•
Read only: x.x Hz
Display of the rated slip determined.
0x2C01:001 Motor parameters: Number of pole pairs
•
Read only
Display of the number of pole pairs calcula
ted from the rated speed and
rated frequency.
0x2C01:004
(PAR 320/004)
Motor parameters: Rated speed
(Motor parameters: Mot. speed)
50 ... [1450] ... 50000 rpm
General motor parameters.
Carry out sengs as specied by motor nameplate data.
0x2C01:005
(PAR 320/005)
Motor parameters: Rated frequency
(Motor parameters: Mot. frequency)
1.0 ... [50.0] ... 1000.0 Hz
Motor control
Opmisaon of motor control
Slip compensaon
87