7.4 Opmisaon of the control loops
The following speed controller, Imax controller and current controller parameters are calcula-
ted and set automacally and in the cour
se of the automac calibraon of the motor.
Details
The calibraon process can be carried out in "energised" or in "non-energised" mode.
The calibraon process takes all controllers into consideraon at the same me; it is not
possible to control the speed controller Imax controller, and current controller separately.
Without carrying out the calibraon, standard values are preset according to the voltage
and power of the inverter.
When the automac calibraon has been carried out, further adaptaon is neither required
nor recommended for typical applicaons.
If these parameters have to be adapted, this has to be done very carefully. An
incorrect seng may hav
e a negave impact on the control system.
7.4.1 Speed controller
Parameter Name / value range / [default seng] Info
0x2900:001
(PAR 332/001)
Speed controller par
ameters: Gain
(Speed controller: Speed contr.: gain)
0.00000 ... [0.00193]* ... 20000.00000 Nm/rpm
Default seng depending on the size.
Gain factor Vp of the speed controller.
0x2900:002
(PAR 332/002)
Speed controller parameters: Reset me
(Speed controller: Speed contr.: me)
1.0 ... [80.0]* ... 6000.0 ms
Default seng depending on the size.
Reset me Ti of the speed controller.
0x2904 Filter me
0.0 ... [2.0] ... 50.0 ms
Filter me for the actual speed value.
7.4.2 Imax controller
Parameter Name / value range / [default seng] Info
0x2B08:001
(PAR 333/001)
V/f Imax con
troller: Gain
(V/f Imax controller: Imax ctrller: gain)
0.000 ... [0.284]* ... 1000.000 Hz/A
Default seng depending on the size.
Gain factor Vp of the Imax controller.
0x2B08:002
(PAR 333/002)
V/f Imax controller: Reset me
(V/f Imax controller: Imax ctrller: me)
1.0 ... [2.3]* ... 2000.0 ms
Default seng depending on the size.
Reset me Ti of the Imax controller.
7.4.3 Current controller
Parameter Name / value range / [default seng] Info
0x2942:001
(PAR 334/001)
Current con
troller parameters: Gain
(Current controller: I-contr.: gain)
0.00 ... [42.55]* ... 750.00 V/A
Default seng depending on the size.
Gain factor Vp of the current controller.
0x2942:002
(PAR 334/002)
Current controller parameters: Reset me
(Current controller: I-contr.: me)
0.01 ... [4.50]* ... 2000.00 ms
Default seng depending on the size.
Reset me Ti of the current controller.
Motor control
Opmisaon of the control loops
Speed controller
89