12.2 Rated data
12.2.1 Connecon to the 230 V system
Inverter I51AE125B I51AE137B I51AE155B I51AE175B I51AE211B I51AE215B I51AE222B
Rated power kW 0.25 0.37 0.55 0.75 1.1 1.5 2.2
Mains voltage range 1/N/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Operang mode S1
Max. surrounding air
temperature
°C
40
S
witching frequency kHz 4
Rated mains current
without mains choke A 4 5.7 7.6 10 14.3 16.7 22.5
with mains choke A 3.6 4.8 7.1 8.8 11.9 13.9 16.9
Rated output current A 1.7 2.4 3.2 4.2 6 7 9.6
Motor cable length
C2 residenal area /
industrial premises
m
15 20
Weight kg 0.75 0.95 1.35
12.2.2 Connecon to the 400 V system
Inverter I51AE137F I51AE155F I51AE175F I51AE211F I51AE215F I51AE222F
Rated power kW 0.37 0.55 0.75 1.1 1.5 2.2
Mains voltage range 3/N/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Operang mode S1
Max. surrounding air
temperature
°C
40
S
witching frequency kHz 4
Rated mains current
without mains choke A 1.8 2.5 3.3 4.4 5.4 7.8
with mains choke A 1.4 2 2.6 3 3.7 5.3
Rated output current A 1.3 1.8 2.4 3.2 3.9 5.6
Motor cable length
C2 residenal area /
industrial premises
m
15 20
Weight kg 0.75 0.95 1.35