Parameter Name / value range / [default seng] Info
0x2D45:002
(PAR 310/002)
Motor phase failure detecon: Curr
ent threshold
(Motor Ø failure: Ø error current)
1.0 ... [5.0] ... 10.0 %
Current threshold for the acvaon of the motor phase failure detecon
funcon.
•
100 % ≡ Maximum current 0x2DDF:002
•
Backgr
ound: in order to be able to reliably detect the failure of a
motor phase, rst a certain must ow for the current sensor system.
The detecon funcon is theref
ore only acvated if the actual value
of the motor current has exceeded the current threshold set here.
•
Display of actual value for the motor current in 0x6078 (PAR 103).
0x2D45:003
(PAR 310/003)
Motor phase failure detecon: Voltage threshold
(Motor Ø failure: Ø error volt.)
0.0 ... [10.0] ... 100.0 V
Voltage threshold for the monitoring of several motor phases.
•
The V/f characterisc control enables the detecon of several failed
motor phases during operaon.
•
Monitoring with regard t
o the failure of several motor phases is acve
if a response that is not "0: No response" is set in 0x2D45:001
(PAR 310/001) and if the motor voltag
e exceeds the voltage threshold
set here.
•
The monitoring funcon is triggered if the level of the motor current
is lower than the device-dependent threshold for longer than 20 ms.
•
The monitoring funcon for the failure of several motor phases can
be deacvated if the value "100.0 V" is set here.
7.7.5 Motor speed monitoring
Use this funcon to monitor the motor speed during running operaon.
Precondions
In order to r
ecord the current motor speed, the drive must run and the motor must rotate.
Parameter Name / value range / [default seng] Info
0x2D44:001
(PAR 350/001)
Overspeed monitoring
: Threshold
(Overspeed monit.: Overspeed: threshold)
50 ... [8000] ... 50000 rpm
Warning/error threshold for motor speed monitoring.
•
If the motor speed reaches the threshold set, the response selected in
0x2D44:002 (PAR 350/002) is eected.
0x2D44:002
(PAR 350/002)
Overspeed monitoring: Response
(Overspeed monit.: Overspeed: response)
•
For possible sengs see descripon for
0x2D45:001 (PAR 310/001). ^ 94
Selecon of the response to the triggering of motor speed monitoring.
3 Error
Motor control
Motor protecon
Motor speed monitoring
95