10.2 Keypad
For the keypad various sengs can be made, which are described in detail in the following
subchapters.
10.2.1 K
eypad language Selecon
Parameter Name / value range / [default seng] Info
0x2863
(PAR 705)
Keypad language
selecon
(Language selecon)
Language selecon for the keypad display.
0 No language selected
1 English
2 German
10.2.2 Keypad setpoint increment
Parameter Name / value range / [default seng] Info
0x2862
(PAR 701)
Keypad setpoin
t increment
(Keypad setpoint)
1 ... [1] ... 100
Adaptaon of the increment for keypad setpoints when a keypad arrow
key is pressed once. The value set serves as a mulplier for the preset
increments.
Preset increments:
•
0.1 Hz for frequency setpoint 0x2601:001 (PAR 202/001).
•
0.01 PUnit for process controller setpoint 0x2601:002 (PAR 202/002).
•
1 % for torque setpoint .
Notes:
•
With a seng > 1, the opon of repeatedly changing the setpoint by
pressing the key for a longer me is deacvated.
•
The seng only has an impact on the keypad setpoints.
Example: with the seng "5", the keypad frequency setpoint is
increased/decreased by 0.5 Hz every me the key is pressed.
10.2.3 Keypad scaling of speed display
Parameter Name / value range / [default seng] Info
0x4002
(PAR 702)
Speed display scaling
(Scaled speed f
actor)
0.00 ... [0.00] ... 650.00
Factor for the scaling of the speed display in 0x400D (PAR 101).
•
With the seng "0.00", no scaling takes place.
•
Example: with the "16.50" and the actual frequency = 50 Hz, 0x400D
(PAR 101) shows the speed "825 rpm".
0x400D
(PAR 101)
Scaled actual value
(Scaled actual value)
•
Read only: x Units
Display of the current speed in applicaon units.
Addional funcons
Keypad
Ke
ypad language Selecon