Parameter Name / value range / [default seng] Info
0x232E:014
(PAR 583/014)
Modbus diagnoscs of last RX data
: Data byte 12
(RX data diagnoscs: Last RxD byte24)
Read only
0x232E:015
(PAR 583/015)
Modbus diagnoscs of last RX data: Data byte 13
(RX data diagnoscs: Last RxD byte26)
Read only
0x232E:016
(PAR 583/016)
Modbus diagnoscs of last RX data
: Data byte 14
(RX data diagnoscs: Last RxD byte28)
Read only
0x232E:017
(PAR 583/017)
Modbus diagnoscs of last RX data
: Data byte 15
(RX data diagnoscs: Last RxD byte30)
Read only
0x232F:001
(PAR 585/001)
Modbus diagnoscs of last TX data: Oset
(TX data diagnoscs: TX data oset)
0 ... [0] ... 240
For purposes of diagnoscs, the last message sent (max. 16 bytes) is
shown in 0x232F:1 ... 16. For longer messages, an oset can be specied
here, indicang from which byte of the message the display of the 16
bytes is to start.
0x232F:002
(PAR 585/002)
Modbus diagnoscs of last TX data: Data byte 0
(TX data diagnoscs: Last TxD byte0)
Read only
Display of the message sent last.
0x232F:003
(PAR 585/003)
Modbus diagnoscs of last TX data: Data byte 1
(TX data diagnoscs: Last TxD Byte1)
Read only
0x232F:004
(PAR 585/004)
Modbus diagnoscs of last TX data: Data byte 2
(TX data diagnoscs: Last TxD byte2)
Read only
0x232F:005
(PAR 585/005)
Modbus diagnoscs of last TX data: Data byte 3
(TX data diagnoscs: Last TxD byte3)
Read only
0x232F:006
(PAR 585/006)
Modbus diagnoscs of last TX data: Data byte 4
(TX data diagnoscs: Last TxD byte4)
Read only
0x232F:007
(PAR 585/007)
Modbus diagnoscs of last TX data
: Data byte 5
(TX data diagnoscs: Last TxD byte5)
Read only
0x232F:008
(PAR 585/008)
Modbus diagnoscs of last TX data: Data byte 6
(TX data diagnoscs: Last TxD byte6)
Read only
0x232F:009
(PAR 585/009)
Modbus diagnoscs of last TX data: Data byte 7
(TX data diagnoscs: Last TxD byte7)
Read only
0x232F:010
(PAR 585/010)
Modbus diagnoscs of last TX data: Data byte 8
(TX data diagnoscs: Last TxD byte8)
Read only
0x232F:011
(PAR 585/011)
Modbus diagnoscs of last TX data: Data byte 9
(TX data diagnoscs: Last TxD byte9)
Read only
0x232F:012
(PAR 585/012)
Modbus diagnoscs of last TX data: Data byte 10
(TX data diagnoscs: Last TxD byte10)
Read only
0x232F:013
(PAR 585/013)
Modbus diagnoscs of last TX data: Data byte 11
(TX data diagnoscs: Last TxD byte11)
Read only
0x232F:014
(PAR 585/014)
Modbus diagnoscs of last TX data: Data byte 12
(TX data diagnoscs: Last TxD byte12)
Read only
0x232F:015
(PAR 585/015)
Modbus diagnoscs of last TX data
: Data byte 13
(TX data diagnoscs: Last TxD byte13)
Read only
0x232F:016
(PAR 585/016)
Modbus diagnoscs of last TX data: Data byte 14
(TX data diagnoscs: Last TxD byte14)
Read only
Conguring the network