Parameter Name / value range / [default seng] Info
0x2820:007
(PAR 712/007)
Holding brake con
trol: Applicaon threshold
(Mech. brake: MB applicaon level)
0.0 ... [0.2] ... 599.0 Hz
Threshold for applying the holding brake for automac mode without
feedforward control (typically for horizontal applicaons).
•
Only eecve if the holding load in 0x2820:008 (PAR 712/008) is set
to 0 %.
•
By seng a threshold, the holding brake can be triggered to close
before the output frequency has reached the value 0 Hz.
•
In order that the brake can work correctly, the threshold for closing
the brake must be set to a value that is greater than or that equals the
minimum frequency 0x2915 (PAR 210).
0x2820:008
(PAR 712/008)
Holding brake control: Holding load
(Mech. brake: MB holding load)
-500.0 ... [0.0] ... 500.0 %
Holding load for automac mode (typically for vercal applicaons).
•
100 % ≡ slip frequency 0x2C02:004 (PAR 351/004)
•
For vercal applicaons w
e recommend starng with the
seng
100 % and then reducing the seng value, if required.
0x2820:015
(PAR 712/015)
Holding brake control: Brake status
(Mech. brake: MB status)
•
Read only
Display of the holding brake status.
0 Acve
1 Brake released
0x2631:049
(PAR 400/049)
Funcon assignment: Release holding brake
(Funcon list: Release brake)
•
Seng can only be changed if controller inhibit is
acve.
•
For possible sengs see descripon for
0x2631:001 (PAR 400/001). ^ 188
Assignment of a trigger for the "Release holding brake" funcon.
Trigger = TRUE: release holding brake in manual mode.
Trigger = FALSE: no acon.
Notes:
•
Funcon is only executed if the operang mode of the holding brake
in 0x2820:001 (PAR 712/001) is set to "Manual [1]".
00 Not connected No trigger assigned (trigger is constantly FALSE).
Addional funcons
Holding brake con
trol
181