Parameter Name / value range / [default seng] Info
0x291A
(PAR 223)
Deceleraon me 2
(Deceleraon me 2)
0.0 ... [5.0] ... 3600.0
s
The deceleraon me set refers to the deceleraon from the maximum
frequency set to standsll. In the case of a lower actual frequency, the
actual deceleraon me is reduced accordingly.
Deceleraon me 2 is acve if
"Motor potenometer" funcon is acve, or
frequency setpoint (absolute value) > auto-change-over threshold
0x291B (PAR 224), or
the trigger assigned in 0x2631:039 (PAR 400/039) of the "Acvate
ramp 2" funcon is TRUE.
Flexible I/O conguraon
Setpoint change-over
Motor potenometer setpoint source
200