Parameter Name / value range / [default seng] Info
79 Torque limit reached TRUE if torque limit has been reached or exceeded. Otherwise FALSE.
80 Follower signal (4 … 20 mA) lost TRUE if follower signal (4 … 20 mA) lower than 2 mA.
81 Error of analog input 1 TRUE if error detecon for analog input 1 has been acvated. Otherwise
FALSE.
The err
or detecon funcon can be congured via the following param-
eters:
•
Monitoring threshold 0x2636:008 (PAR 430/008)
•
Monitoring condion 0x2636:009 (PAR 430/009)
•
Monitoring response 0x2636:010 (PAR 430/010)
4Analog input 1 ^ 211
82 Error of analog input 2 TRUE if error detecon for analog input 2 has been acvated. Otherwise
FALSE.
The err
or detecon funcon can be congured via the following param-
eters:
•
Monitoring threshold 0x2637:008 (PAR 431/008)
•
Monitoring condion 0x2637:009 (PAR 431/009)
•
Monitoring response 0x2637:010 (PAR 431/010)
4Analog input 2 ^ 213
83 Load loss TRUE if current motor current < threshold for load loss detecon for at
least the delay for load loss detecon. Otherwise F
ALSE.
•
Display of the present motor current in 0x6078 (PAR 103).
•
Seng Threshold in 0x4006:001 (PAR 710/001).
•
Seng Deceleraonin 0x4006:002 (PAR 710/002).
4Load loss detecon ^ 158
104 Local control acve TRUE if local keypad control ("LOC") acve. Otherwise FALSE.
105 Remote control acve TRUE if remote con
trol ("REM") via terminals, network, etc. acve. Oth-
erwise FALSE.
106 Manual setpoint selecon acve TRUE if manual setpoint selecon ("MAN") via keypad acve. Otherwise
FALSE.
•
Selecon of the trigger for the "Setpoint = Keypad" funcon in
0x2631:016 (PAR 400/016).
107 Automac setpoint selecon acve TRUE if automac setpoint selecon ("AUTO") via terminals, network,
etc. acve. Otherwise FALSE.
108 Parameter set 1 acve TRUE if parameter set 1 is loaded and acve. Otherwise FALSE.
109 Parameter set 2 acve TRUE if parameter set 2 is loaded and acve. Otherwise FALSE.
110 Parameter set 3 acve TRUE if parameter set 3 is loaded and acve. Otherwise FALSE.
111 Parameter set 4 acve TRUE if parameter set 4 is loaded and acve. Otherwise FALSE.
112 Loading of parameters successful TRUE aer any parameter set has been loaded. Otherwise FALSE.
113 Loading of parameters faulty TRUE if any of the parameter sets could not be loaded. Otherwise FALSE.
114 Network control mode acve TRUE if the network requests the control. Otherwise FALSE.
115 Release holding brake TRUE if the holding brake is released (or should be released). Otherwise
FALSE.
0x2635:001
(PAR 421/001)
Inversion of digit
al outputs: Relay
(DO inversion: Relay inverted)
Relay inversion
0 Not inverted
1 Inverted
0x4018:003 Relay: Cutout delay
0.000 ... [0.020] ... 65.535 s
Switch-o delay for the relay.
0x4018:004 Relay: Switch-on delay
0.000 ... [0.020] ... 65.535 s
Switch-on delay for the relay.
0x4018:005 Relay: Relay state
•
Read only
Display of the logic state of the relay.
0 FALSE
1 TRUE
0x4018:006 Relay: Trigger signal state
•
Read only
Display of the logic sta
te of the trigger signal for the relay (without tak-
ing a ON/OFF delay set and inversion into consideraon).
0 FALSE
1 TRUE
0x4018:007 Relay: Switching cycles
•
Read only
Display of the previous relay switching cycles.
Flexible I/O conguraon
Conguraon of digital outputs
Relay
217