Parameter Name / value range / [default seng] Info
0x29C0:002 Field controller sengs: Reset me
1.0 ... [45.5]* ... 6000.0 ms
Default seng depending on the size.
R
eset me Tn of the eld controller.
0x29E0:001 Field weakening controller sengs: Gain
0.000 ... [0.000]* ... 2000000.000 Vs/V
Default seng depending on the size.
Gain factor Vp of the eld weakening controller.
0x29E0:002 Field weakening controller sengs: Reset me
1.0 ... [1478.3]* ... 240000.0 ms
Default seng depending on the size.
R
eset me Tn of the eld weakening controller.
0x2B40:001 SLVC: Gain
0.0000 ... [0.2686]* ... 1000.0000 Hz/A
Default seng depending on the size.
Gain of the SL
VC-Q controller.
0x2B40:002 SLVC: Reset me
1.0 ... [2.3]* ... 2000.0 ms
Default seng depending on the size.
Reset me of the SLVC-Q controller.
0x2900:001
(PAR 332/001)
Speed controller parameters: Gain
(Speed controller: Speed contr.: gain)
0.00000 ... [0.00193]* ... 20000.00000 Nm/rpm
Default seng depending on the size.
Gain factor Vp of the speed controller.
0x2900:002
(PAR 332/002)
Speed controller parameters: Reset me
(Speed controller: Speed contr.: me)
1.0 ... [80.0]* ... 6000.0 ms
Default seng depending on the size.
Reset me Ti of the speed controller.
0x2915
(PAR 210)
Minimum frequency
(Min. frequency)
0.0 ... [0.0] ... 599.0
Hz
Lower limit value for all frequency setpoints.
0x2916
(PAR 211)
Maximum frequency
(Max. frequency)
0.0 ... [50.0] ... 599.0 Hz
Upper limit value for all frequency setpoints.
0x2942:001
(PAR 334/001)
Current controller parameters: Gain
(Current controller: I-contr.: gain)
0.00 ... [42.55]* ... 750.00 V/A
Default seng depending on the size.
Gain factor Vp of the current controller.
0x2942:002
(PAR 334/002)
Current controller parameters: Reset me
(Current controller: I-contr.: me)
0.01 ... [4.50]* ... 2000.00 ms
Default seng depending on the size.
Reset me Ti of the current controller.
0x2BA1:003
(PAR 718/003)
Flying restart circuit: Restart me
(Flying restart circuit: Flying restart me)
1 ... [5911]* ... 60000 ms
Default seng depending on the size.
Restart me for ying restart process.
The duraon of the ying restart process can be inuenced by the set-
ting of the restart me.
A reducon of the restart me causes an accelerated ying restart
process and therefore a reduced ying restart duraon.
0x6073
(PAR 324)
Max current
(Max current)
0.0 ... [200.0] ... 3000.0 %
Maximum overload current of the inverter.
100 % ≡ rated motor current 0x6075 (PAR 323)
If the current consumpon of the motor exceeds this current limit,
the inverter changes its dynamic behaviour, in order to counteract
this exceedance.
If the change in the dynamic behaviour carried out by the inverter
does not result in exing the overcurrent state, the inverter outputs
an error.
Note!
This parameter is not idencal to the so-called ulmate motor current
I
ULT
!
The ulmate motor current set in 0x2D46:001 (PAR 353/001) is a limit
value for synchronous motors that serves to protect their magnets.
The value to be set here should always be considerably below the ul-
mate motor current!
Motor control
Motor control selecon
Sensorless v
ector control (SLVC)
83