2 If there is any clearance, turn the two adjustment screws (B) clockwise or counterclockwise to lift or lower the rear
side.
ADF registration adjustment
1 Enter the Configuration Menu, and then navigate to:
Scanner Manual Registration > Print Quick Test
2 Place the Quick Tests page on the ADF and then select Copy Quick Test.
Do this step to view the current ADF registration values.
3 Select from the following options:
• ADF—This setting adjusts the ADF registration of a simplex scanner.
• ADF Front—This setting adjusts the ADF front side registration of a duplex scanner.
• ADF Back—This setting adjusts the ADF back side registration of a duplex scanner.
The current values of the horizontal adjust and top margin registration settings appear.
4 Adjust the value of the horizontal adjust and top margin settings.
5 Apply the changes.
6 Repeat step 2 to view the updated values.
7 Repeat steps 3 through 5 to make further adjustments.
7421
Repair information
259