EasyManua.ls Logo

Lexmark MX912dxe - Induction Heater Power Supply (IHPS) Removal; Noise Filter Board Removal

Lexmark MX912dxe
827 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Induction heater power supply (IHPS) removal
1 Remove the scanner interface cable cover. See “Scanner interface cable cover removal” on page 344.
2 Remove the controller board access cover. See “Controller board access cover removal” on page 345.
3 Remove the engine board cover. See “Engine board cover removal” on page 346.
4 Remove the upper rear cover. See “Upper rear cover removal” on page 346.
5 Remove the induction heater power supply shield. See “IHPS shield removal” on page 347.
6 Remove the induction heater magnetic erase board. See Induction heater magnetic erase board (IHMEB) removal”
on page 348.
7 Disconnect the cables, and then remove the eight screws (A).
8 Remove the power supply.
Noise filter board removal
1 Remove the scanner interface cable cover. See “Scanner interface cable cover removal” on page 344.
2 Remove the controller board access cover. See “Controller board access cover removal” on page 345.
3 Remove the engine board cover. See “Engine board cover removal” on page 346.
4 Remove the upper rear cover. See “Upper rear cover removal” on page 346.
5 Remove the IHPS shield. See “IHPS shield removal” on page 347.
7421
Repair information
350