5 Disconnect the cable (B), and then release it from the cable clips.
6 Remove the assembly.
MPF empty actuator removal
Note: This part is not a FRU.
1 Remove the tray 2 transport guide. See “Tray 2 transport guide” on page 296.
2 Remove the MPF. See “MPF removal” on page 297.
3 Remove the MPF tray. See “MPF tray removal” on page 298.
4 Remove the screw (A), and then remove the actuator with spring.
Installation note: Make sure that the spring is correctly positioned on the actuator base.
7421
Repair information
309