EasyManua.ls Logo

Manitowoc GROVE GMK4090 - Checks after Starting the Engine

Manitowoc GROVE GMK4090
994 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Starting the engine for driving – switching it off
4.1 Starting the engine from the driver's cab
4 - 16 3 302 736 en Operating manual
GMK4090
xx.xx.xxxx
4.1.9 Checks after starting the engine
Start menu and
on-board
computer
Check if the display area of the main
menu (1) or the on-board computer
display (2) shows any red symbols
Display area (1) – when a symbol is red;
à Malfunctions on the engine, p. 8 - 19.
On-board computer display (2) – when a
warning message or symbol is shown;
à Warning and malfunction messages on the
on-board computer display
, p. 8 - 9.
If a red symbol lights up, or if a message
demands it, switch the engine off immedi-
ately.
Also check the following displays
The colour of the bar under the value indicates
the range within which the value lies.
S
Risk of damage to the engine
Observe the symbols and messages in the display area of the main menu
and in the on-board computer. By this means you avoid low oil pressure
leading to engine damage.
1 Voltage in volts
2 The hydraulic oil temperature in °C (°F)
3
AdBlue supply in percentage
Green: Value OK
Yellow: Limit value almost reached
Red: Limit value exceeded (or not
reached) – warning message;
à p. 8 - 13.

Table of Contents