Malfunctions in driving mode
8.4 Troubleshooting
Operating manual 3 302 736 en 8 - 21
GMK4090
xx.xx.xxxx
When operating
with the dual tank
The following specifications only apply when the dual tank is fitted as addi-
tional equipment.
8.4.2 Faults on the Adblue system
H
Further information; à Warning messages on the CCS display, p. 8 - 13.
Malfunction Cause Solution
Fuel supply cannot be
switched over
Fuse F13 blown Replace blown fuses;
à p. 8 - 49
Engine does not start
Starter turns
Dual tank empty 1. Refuel;
à p. 4 - 5
2. Bleed the fuel system;
à Maintenance manual
à Operating manual of
the engine manufacturer
Malfunction Cause Solution
Lights up
Flashing
AdBlue level in tank at reserve
level
AdBlue tank empty
Fill up with AdBlue;
à p. 4 - 7
Light up
AdBlue tank sensor faulty
Error on the AdBlue dosing
unit
AdBlue lines blocked
Temperature sensor faulty
Open circuit on AdBlue
system
Exhaust gas sensor faulty
Have the exhaust system
checked by
Manitowoc
Crane Care
, an authorised
GROVE retailer or an
authorised specialised
repair shop.
AdBlue system not
working
Fuse F6/8 blown Replace blown fuses;
à p. 8 - 49