EasyManuals Logo

Manitowoc GROVE GMK4090 User Manual

Manitowoc GROVE GMK4090
994 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #947 background imageLoading...
Page #947 background image
Malfunctions during crane operation
14.6 Hydraulic emergency operation with the hand pump
Operating manual 3 302 736 en 14 - 51
GMK4090
xx.xx.xxxx
14.6.3 Establishing the required hydraulic circuits
You must switch over the necessary valves to establish a hydraulic circuit.
The valves 1 to 3 are secured against unintentional switching over.
Releasing/secur-
ing valves
Releasing/securing is described for a valve. The procedure is identical for
valves 1 to 3.
Release – for the emergency operation
• Unscrew the handle (1).
• Move the disc (2) to position A.
• Fasten the handle (1).
Rigging – for crane operation
The valve must be closed.
• Unscrew the handle (1).
• Move the disc (2) to position B.
• Fasten the handle (1).
s
S
Danger due to operating error
Following emergency operation, secure the valves 1 to 3 in position B again
for crane operation.
This prevents uncontrolled crane movements when switching the crane's
hydraulic system on.

Table of Contents

Other manuals for Manitowoc GROVE GMK4090

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK4090 and is the answer not in the manual?

Manitowoc GROVE GMK4090 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK4090
CategoryConstruction Equipment
LanguageEnglish

Related product manuals