Driving
5.3 Driving the truck crane and switching it off
Operating manual 3 302 736 en 5 - 45
GMK4090
xx.xx.xxxx
5.3.6 Overriding torque reduction
If the AdBlue tank is empty, torque reduction is activated via the engine con-
trol system.
You can override torque reduction up to 3 times.
– If the level in the
AdBlue tank falls to the reserve level, then the symbol (1)
is displayed.
• Immediately fill up with AdBlue; à AdBlue tank, p. 4 - 7.
– If the
AdBlue tank is empty, the light (1) will flash.
The engine torque is reduced the next time the engine is started.
The engine torque is reduced.
• Push the button (1) upwards to override the torque reduction.
You can override torque reduction up to 3 times.