Driving modes
6.4 Installing/removing the outrigger beams
6 - 24 3 302 736 en Operating manual
GMK4090
xx.xx.xxxx
6.4.7 Disconnecting/establishing hydraulic connection
There is a valve block on each outrigger beam. The position of the valve
block may differ from the drawings, depending on the outrigger beam.
Undoing the connection
Always disconnect all connections (4).
• Hold the hose (1) firmly.
• Pull the lock (2) against the stop. The hose is
pushed out of the connection (3).
• Seal all connecting points.
Making the connection
Always establish all connections (4). The
assignment is specified by colour designa-
tions.
• Insert the hose (1) into the connection (3).
• The lock (2) engages.