Starting the engine for driving – switching it off
4.2 Switch off the engine
4 - 20 3 302 736 en Operating manual
GMK4090
xx.xx.xxxx
4.2.2 Using the emergency stop switches
H
Do not operate the emergency stop switch to switch the engine off in nor-
mal operation. Only operate the emergency stop switch in an emergency
situation.
Three emergency stop switches are provided
for emergency use:
• Press an active emergency stop switch. (1),
(2) or (3).
– The switch latches.
– The engine shuts down.
If an air intake inhibitor is present, this is then
triggered.
Emergency stop
switch, resetting
You can restart the engine only after you have reset the emergency stop
switch.
• Switch off the ignition.
• Turn the actuated emergency stop switch until it disengages again.
If air intake inhibitors are fitted, they must be released;
à Opening the air
intake inhibitor
, p. 4 - 21.
1 At the carrier – always active
2 In the crane cab – always active
3 Only active for connected hand-held con-
trol – in addition to (1) and (2)

Table of Contents

Other manuals for Manitowoc GROVE GMK4090

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK4090 and is the answer not in the manual?

Manitowoc GROVE GMK4090 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK4090
CategoryConstruction Equipment
LanguageEnglish

Related product manuals