Starting the engine for driving – switching it off
4.2 Switch off the engine
4 - 20 3 302 736 en Operating manual
GMK4090
xx.xx.xxxx
4.2.2 Using the emergency stop switches
H
Do not operate the emergency stop switch to switch the engine off in nor-
mal operation. Only operate the emergency stop switch in an emergency
situation.
Three emergency stop switches are provided
for emergency use:
• Press an active emergency stop switch. (1),
(2) or (3).
– The switch latches.
– The engine shuts down.
If an air intake inhibitor is present, this is then
triggered.
Emergency stop
switch, resetting
You can restart the engine only after you have reset the emergency stop
switch.
• Switch off the ignition.
• Turn the actuated emergency stop switch until it disengages again.
If air intake inhibitors are fitted, they must be released;
à Opening the air
intake inhibitor
, p. 4 - 21.
1 At the carrier – always active
2 In the crane cab – always active
3 Only active for connected hand-held con-
trol – in addition to (1) and (2)