EasyManuals Logo

Manitowoc GROVE GMK4090 User Manual

Manitowoc GROVE GMK4090
994 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #553 background imageLoading...
Page #553 background image
Crane operation
11.1 Before operating the crane
Operating manual 3 302 736 en 11 - 5
GMK4090
xx.xx.xxxx
11.1.2 Check the condition of the truck crane
Fuel tank auxiliary
heater
Use the same fuel as for the engine or use EL heating oil for refuelling.
• The display (2) shows the fuel level in the
tank (1).
• Refuel in due time and seal the tank (1) with
the cap.
Visual inspection Walk around the truck crane and look out in particular for leaking oil, fuel or
coolant.
s
S
Danger of fire due to flammable gases
Turn off the engine and heating systems before refuelling.
G
Danger if the crane cannot be unrigged
If oil is lost, you may no longer be able to move the crane. Not even in emer-
gency mode.
O
Risk of environmental damage due to leaking consumables
Immediately repair or have repaired oil, fuel and coolant leakages.
This prevents oil or fuel seeping into the ground or polluting waters.

Table of Contents

Other manuals for Manitowoc GROVE GMK4090

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK4090 and is the answer not in the manual?

Manitowoc GROVE GMK4090 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK4090
CategoryConstruction Equipment
LanguageEnglish

Related product manuals