Malfunctions during crane operation
14.5 Emergency operations and programs
14 - 44 3 302 736 en Operating manual
GMK4090
xx.xx.xxxx
Stopping move-
ments in emer-
gencies
This section applies only to the situation where a motion does not stop after
releasing the Function button.
• Press the emergency stop switch (1) – the engine switches off.
The switch (1) latches.
After activating an emergency stop switch;
à Emergency stop switch, reset-
ting
, p. 4 - 20.
H
You can also use the emergency stop switch on the the carrier or in the
crane cab;
à p. 14 - 1.
Switch off the
engine
You can switch off the engine only by using the hand-held control.
• Stop all crane movements.
• Press the button (1) – the engine will switch off.
14.5.5 Notes on slewing in emergency operation
For the Standard
slewing range
type
If the MAXbase slewing range type is activated; Ã p. 14 - 46.
Slewing is not monitored by the RCL in emergency operation.
G
Risk of overturning when slewing in emergency operation
Check the table to see if slewing is permitted. Adhere to the enabled work-
ing range specified in the
Lifting capacity table and observe the restrictions
described.
If you have any doubts, contact
Manitowoc Crane Care.