Crane operation
11.4 Operation of the rated capacity limiter
Operating manual 3 302 736 en 11 - 63
GMK4090
xx.xx.xxxx
To raise the boom You can release the raise boom function for derricking again within the per-
mitted working range.
H
This function is only active if the current degree of utilisation lies above
100% and the crane movements are switched off.
Raising the main boom
• Press the button (1) once – the information
message (2) is displayed.
– Raising is enabled.
– The speed is reduced to 50%.
• Raise the main boom until the degree of
utilisation is less than 100%.
– The crane movements will then be ena-
bled again.
– The button (1) has no function.
H
The raising of the main boom will be shut down if the main boom angle is
too great. Then all you can do is set the load down.
Switch off function
– For degree of utilisation above 100%
The function will be switched off if you:
– press button (1) again, or
– switch off the ignition.
– For degree of utilisation below 100%
The function is switched off automatically.
s

Table of Contents

Other manuals for Manitowoc GROVE GMK4090

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK4090 and is the answer not in the manual?

Manitowoc GROVE GMK4090 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK4090
CategoryConstruction Equipment
LanguageEnglish

Related product manuals