EasyManua.ls Logo

Manitowoc GROVE GMK4090 - Page 717

Manitowoc GROVE GMK4090
994 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rigging work
12.2 Choice of a suitable positioning site
Operating manual 3 302 736 en 12 - 13
GMK4090
xx.xx.xxxx
Load-bearing area
Now calculate the required load-bearing area.
Check that the surface of the outrigger pad (à p. 1 - 17) is larger than the
calculated load-bearing area. If the surface of the outrigger pad is smaller,
you will need to enlarge the load-bearing area.
Example for calculating the required load-bearing area:
If the outrigger pressure is 25 t and the ground has a load bearing capacity of
40 t/m
2
. Then the required ground bearing area for this supporting cylinder is
0.625 m
2
(= 6,250 cm
2
).
If the outrigger pad has a surface of 2,000 cm
2
, you would need to enlarge the
ground bearing area by packing the outrigger pads; à p. 12 - 55.
G
Danger of overturning if the load-bearing area is too small
Ensure that the actual load-bearing area is at least as large as specified in
the table.
This prevents the ground giving way and the truck crane overturning.