Page #910 background image
Malfunctions during crane operation
14.4 Troubleshooting
14 - 14 3 302 736 en Operating manual
GMK4090
xx.xx.xxxx
Only the lowering func-
tion works
Lifting limit switch
approached, lamp lights up
Leave the shutdown
range and lower the hoist.
RCL shutdown, lamp lights up Leave the shutdown
range;
à p. 11 - 56
Control unit fuse blown Replace the blown fuse;
à p. 14 - 72
Lifting, lowering or high-
speed mode function not
working
Function disabled by CCS If required, acknowledge
error message once and
briefly turn off the ignition
– it if occurs again, notify
Manitowoc Crane Care
No lift function Control unit fuse blown Replace the blown fuse;
à p. 14 - 72
Lifting or lowering is
either not possible at all
or only at a low speed
Speed limited Increase limit;
à p. 11 - 123
Lifting or lowering func-
tion cannot be
switched off
CCS malfunction Emergency stop switch;
à p. 14 - 1
No response to control
lever movements
CCS malfunction for operat-
ing elements in the crane cab
Unrig using hand-held
control;
à p. 14 - 41
Malfunction Cause Solution

Table of Contents

Other manuals for Manitowoc GROVE GMK4090

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK4090 and is the answer not in the manual?

Manitowoc GROVE GMK4090 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK4090
CategoryConstruction Equipment
LanguageEnglish

Related product manuals