EasyManua.ls Logo

Manitowoc GROVE GMK4090 - Page 915

Manitowoc GROVE GMK4090
994 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Malfunctions during crane operation
14.4 Troubleshooting
Operating manual 3 302 736 en 14 - 19
GMK4090
xx.xx.xxxx
Slewing only possible in
one direction
Shutdown angle of a limited
slewing range reached (addi-
tional equipment).
Enter the RCL code for a
slewing range of 360°
(
Standard) or reduce the
working radius (
MAXbase)
or slew in the opposite
direction to leave the
shutdown angle
Slewing not possible or
only at low speed
Speed limited Increase limit;
à p. 11 - 123
Slewing gear no longer
responds to the control
lever movement
CCS malfunction Emergency stop switch;
à p. 14 - 1
No response to control
lever movements
CCS malfunction for operat-
ing elements in the crane cab
Unrig using hand-held
control;
à p. 14 - 41
Malfunction Cause Solution

Table of Contents