Troubleshooting automation 403
PRO Series Live Audio Systems
Owner’s Manual
c
c-lib file error File and
Automation
Critical internal error. This is an indication of a
serious error. Contact Midas
Technical Support.
c-lib error File and
Automation
Critical internal error. This is an indication of a
serious error. Contact Midas
Technical Support.
c-lib process error File and
Automation
Critical internal error. This is an indication of a
serious error. Contact Midas
Technical Support.
d
device utilisation
policy violation
File and
Automation
The device is full. If necessary, backup some
files and delete them from
the device to free up some
memory.
e
empty point
scene index
File and
Automation
An attempt was made to
navigate an empty point
scene index.
Try again. If unsuccessful,
and if the file is a show file,
try a backup file, if one is
available.
event is already
active
Automation Critical internal error. This is an indication of a
serious error. Contact Midas
Technical Support.
f
failed to add to
lock list
File A device or file could not be
‘locked’ to prevent another
task accessing it while it is in
use.
Although, in practice, it is
highly unlikely to occur, this
error may indicate a serious
system failure. Contact
Midas Technical Support.
failed to add
scene
File and
Automation
The scene could not be
added.
Try again.
failed to allocate
memory
Automation The MC was unable to
allocate sufficient memory
(RAM) to complete the task.
Switch off the PRO Series
Control Centre and switch it
back on again.
If the problem persists, it
could be an indication of a
serious error. Contact Midas
Technical Support.
failed to configure
scope mask
Automation The ‘copy and paste through
scenes’ operation failed.
Try again. If repeated
attempts fail, contact Midas
Technical Support.
failed to create
show
Automation A new show could not be
created.
Try again. If repeated
attempts fail, contact Midas
Technical Support.
failed to
deschedule event
Automation Critical internal error. This is an indication of a
serious error. Contact Midas
Technical Support.
failed to schedule
event
Automation Critical internal error. This is an indication of a
serious error. Contact Midas
Technical Support.
Error Message System(s) Problem Solution

Table of Contents

Other manuals for Midas PRO SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midas PRO SERIES and is the answer not in the manual?

Midas PRO SERIES Specifications

General IconGeneral
SeriesPRO SERIES
Sample Rate96 kHz
Word ClockYes
TypeDigital Mixing Console
Mix BusesUp to 24
ConnectivityAES50
Control SurfaceMotorized Faders
EQ Bands4-band Parametric EQ per channel
EffectsMultiple internal effects engines
Frequency Response20 Hz - 20 kHz
Processing40-bit floating point