© 2011 MIMAKI ENGINEERING CO.,LTD. 6.1.2 R.2.0 P.2
6.1.2 Key Panel Assy
1
2
3
4
5
6
7
8
4. Disconnect the following Connecters.
1),Power Switch Relay Connector
2),Emergency Switch Relay Connector
5. Remove the Side Cover of right and left.
6. Remove the Key Panel Assy. (Four Screws)
Screw : P4x8SMW x4
The following process may be required at maintenance such as parts replacement.
7. Remove the Front Panel. (Five Screws)
Emergency Switch Relay Connector
Power Switch Relay Connector
Remove the Side Cover of right and left.
Front Panel
Maintenance Manual > Disassembly and Reassembly > Covers > Key Panel Assy
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark