Maintenance Manual > Disassembly and Reassembly > Ink-related Parts > Wipe Suction Pump Assy.
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
Rev.
6.2.5 Wipe Suction Pump Assy.
Procedures
1. Turn the main power OFF.
2. Remove the following covers:
• Rear panel
3. Open the Waste Ink Tank Door and disconnect the relay con-
nector.
4. Disconnect the Tube and remove the Wipe Suction Pump Assy.
Screw : P3x8SMW x4
5. Perform the assembly by reversing the disassembly procedure.
To turn power off, be sure to turn the main power OFF.
Be sure to wear Protective Glasses and Working Gloves during the work operation.
Wipe Suction Pump Assy.
Disconnect the Tube