© 2011 MIMAKI ENGINEERING CO.,LTD. 6.2.4 R.2.0 P.1
1
2
3
4
5
6
7
8
Maintenance Manual > Disassembly and Reassembly > Ink-related Parts > Station Assy.
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
6.2.4 Station Assy.
Description of this section
This section provides the procedure for removing the unit for easier maintenance of certain parts, such as the Pump
Head and Wiper Assy.
Procedures
1. Move the Y-Bar to the farthest position.
2. Turn the main power OFF.
3. Remove the following covers:
• Front Cover •Rear Cover-Right •Station Cover
4. Open the Waste Ink Tank Door and remove the Waste Ink Tank.
5. Move the Carriage to the far left.
6. Disconnect the relay connector of the Diaphragm Pump.
7. Disconnect the black tube of the Nozzle Suction Bottle.
8. Disconnect the connecter from the Wiper Motor.
9. Disconnect the connector of the Pump Motor.
( 3042 Pump3 PCB [CN10] )
10. Disconnect the connecter of the Wiper Sensor.
( 3042 Pump3 PCB [CN5] )
To turn power off, be sure to turn the main power OFF.
Be sure to wear Protective Glasses and Working Gloves during the work operation.
Spread the media or the like around the Carriage not to soil the surroundings.
Take care not to stain any object by ink dripping
Connector of the
Pump Motor
Connecter of the Wiper
Sensor
Wiper Motor