© 2011 MIMAKI ENGINEERING CO.,LTD. 6.7.3 R.2.0 P.1
1
2
3
4
5
6
7
8
Maintenance Manual > Disassembly and Reassembly > UV Parts > Cooling Water Pump
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
6.7.3 Cooling Water Pump
Procedures
1. Drain the cooling water completely.
Follow the procedure given in
”4.2.8 EXCHANGE LED UV ”
2. Turn the main power OFF.
3. Remove the UV Cooling Unit.
Follow the procedure given in
” 6.7.2 UV Cooling Unit ”
4. Remove the Cooling Water Pump.
Screw : P3x10SMW x2
5. Reverse the disassembly procedure for reassembly.
To turn power off, be sure to turn the main power OFF.
Be sure to wear Protective Glasses and Working Gloves during the work operation.
Cooling Water Pump
UV Cooling Unit.