Maintenance Manual > Disassembly and Reassembly > Sensors > Work area sensor
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
Rev.
6.5.3 Work area sensor
Working Procedure
1. Turn the main power off.
2. Remove the following covers:
Right cover
Left cover
Rear cover
Rear Right cover
Disassembly of the “
Projection of the light side”
3. Loosen the Cable fixing.
4. Take the Work area sensor BKT off.
5. Disconnect the connector.
“CN8” of the 3042 Pump3 PCB Assy.
6. Take the sensor off from the Work area sensor BKT.
•Fixing screw x2
To turn power off, be sure to turn the main power OFF.
Work area sensor
Projection of the light side
Work area sensor
Light receiving side
Work area sensor
BKT
Cable fxing
3042 Pump3 PCB Assy.
CN8
Fixing screw x2