6.5.3 Work area sensor
1
2
3
4
5
6
7
8
Disassembly of the “
Light receiving side”
7. Loosen the Cable fixing.
8. Take the Work area sensor BKT off.
9. Disconnect the connector.
“CN27” of the 3042 Slider relay PCB Assy.
10. Take the sensor off from the Work area sensor BKT.
•Fixing screw x2
11. Perform the assembly by reversing the disassembly procedure.
Work area sensor
BKT
Cable fxing
3042 Slider relay PCB Assy
CN27
Fixing screw x2
After assembling, be sure to adjust the light axis.
Refer to “ 4.3.5 Work Area Sensor Height
Adjustment
Maintenance Manual > Disassembly and Reassembly > Sensors > Work area sensor