EasyManua.ls Logo

MIMAKI UJF-3042 - 2011 Mimaki Engineering Co.,Ltd

MIMAKI UJF-3042
243 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2011 MIMAKI ENGINEERING CO.,LTD. 6.3.8 R.2.0 P.1
1
2
3
4
5
6
7
8
Maintenance Manual > Disassembly and Reassembly > Driving Parts > Linear Encorder Scale
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
Rev.
6.3.8 Linear Encorder Scale
Working Procedure
1. Turn the main power OFF
2. Remove the Front Cover.
3. Take the Scale hook off.
Remove the spring(Scale SP).
4. Remove the attachment on the right side (scale holder R).
5. Remove the Scale hook from the Linear Encorder Scale.
Remove the two screws.
6. Perform the assembly by reversing the disassembly procedure.
To turn power off, be sure to turn the main power OFF.
Linear Encoder Scale
Spring(Scale SP)
Scale hook
Remove the screws.
It is sandwiched between plates.

Table of Contents