EasyManua.ls Logo

MIMAKI UJF-3042 - 2011 Mimaki Engineering Co.,Ltd

MIMAKI UJF-3042
243 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2011 MIMAKI ENGINEERING CO.,LTD. 7.2.2 R.2.0 P.2
7.2.2 Discharging defect cannot be improved by cleaning.
1
2
3
4
5
6
7
8
Maintenance Manual > Troubleshooting > Detailed Methods of Coping with the Malfunctions > Discharging defect can-
Model UJF-3042/FX Issued 2010.08.27
Revised
2011.09.30
F/W ver
1.80 / 1.00
Remark
2.0
Rev.
Countermeasure 2
Required items
Work procedure
1. Turn the power ON.
2. Select menu of the “MAINTENANCE” of “FUNCTION”.
3. Select menu of the “MENT :HEAD MENT” of “STATION”
from “MAINTENANCE”.
The carriage moves to the center of the front edge.
4. Open the Front cover TB.
5. Remove the Front cover.
6. Place a tray for cleaning liquid such as a stainless steel bat
under the head.
1 Syringe kit for head washing (Type No. A103291)
2 Tube kit (Type No. A103348)
3 Cleaning liquid bottle (Type No. A102452)
4 Stainless steel bat
5 Phillips screwdriver
Syringe kit for head washing
Tube kit
<LOCAL>
MAINTENANCE
STATION <ent>
STATION
MENT :HEAD MENT
FUNCTION
MAINTENANCE <ent>
Front cover TB
Front cover
Stainless steel bat

Table of Contents