© 2011 MIMAKI ENGINEERING CO.,LTD. 6.7.1 R.2.0 P.4
6.7.1 LED UV UNIT
1
2
3
4
5
6
7
8
12. Remove the Reflector BKT.
•Fixing screw x2
13. Remove the Glass Holder and the Glass.
•Fixing screw x2
14. Take the Glass cushions out.
This is the end of disassembling.
15. Reverse the disassembly procedure for reassembly.
Reflector BKT
Glass
Glass
Holder
Glass cushion x4
Be careful not to lose it.
LED UV Irradiation Assy
It is strictly prohibited to perform maintenance by
disassembling more from the status indicated in
the left figure.
The Assy in the left figure is assembled in the
factory. Therefore, to disassemble, assemble and
use parts again in the field may cause problem of
heat release defect etc.
Maintenance Manual > Disassembly and Reassembly > UV Parts > LED UV UNIT