© 2011 MIMAKI ENGINEERING CO.,LTD. 6.4.3 R.2.0 P.1
1
2
3
4
5
6
7
8
Maintenance Manual > Disassembly and Reassembly > PCBs > 3042 Slider Relay PCB Assy
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
Rev.
6.4.3 3042 Slider Relay PCB Assy
Procedures
1. Turn the main power OFF.
2. Remove the Rear cover.
3. Disconnect all connectors on PCB.
4. Remove the 3042 Slider Relay PCB Assy.
Screw : P3x8SMW x4
5. Reverse the disassembly procedure for reassembly.
To turn power off, be sure to turn the main power OFF.
Be sure to start the work after confirming the working process.
(Refer to “3.3.2 Replacement of 3042 Slider Relay PCB Assy”)
3042 Slider Relay PCBAssy
.
3042 Slider Relay PCB Assy.
Four screws
When the PCB has been replaced, do not forget to
connect the following Connecters.
1),3042_Slider Relay Power short Assy (CN1)
2),IPPR3_Cascade short 13 Assy (CN25)
Make sure to perform the followings after reassem-
bling.
Restore the parameters backed up in the Main PCB
for this board.
1), Turn on the power while holding down the
right and left keys at the same time to enter the
system parameter input mode.
2), Enter "4" in [INITIAL] of the system parame-
ter number 56, and then press ENTER key.
3), Restart the machine.