Maintenance Manual > Adjustment > Adjustment Items > TABLE ADJUST
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver 1.80 / 1.00 Remark
2.0
Rev.
4.2.12 TABLE ADJUST
Outline
[#TABLE ADJUST] consists of the following 4 items.
Procedures of GAP PIN
1. Display [#ADJUST] -> [TABLE ADJUST].
2. 2. Set ON/OFF of the slider.
[]/[] : Switches
3. Confirm with the [ENTER] key to terminate the setting.
[ENTER]: Confirms
[END]: Return
Item Function
GAP PIN Measure the Head gap and register the measured value, and then adjust it to the length of Gap pin.
Z-ORIGIN SENSOR Compensate the height of Z-origin sensor automatically.
TABLE CHECK Measure the height of specified point with the Gap Pin, and indicate the relative value from the reference point
(1.1).
The description is omitted in this manual since the adjustment is impossible in field.
FLAT PATTERN Draws the pattern to check the flatness of table.
FUNCTION
#ADJUST <ent>
#ADJUST
TABLE ADJUST <ent>
#TABLE ADJUST
SLIDER :ON
OFF
#TABLE ADJUST
CPMPLETED :ent