Maintenance Manual > Disassembly and Reassembly > UV Parts > UV Cooling Unit
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
Rev.
6.7.2 UV Cooling Unit
Procedures
1. Drain the cooling water completely.
Follow the procedure given in
4.2.8 EXCHANGE LED UV
2. Turn the main power OFF.
3. Remove the following covers:
• Front Cover
• Front-Left Cover
4. Remove the water tube (IN) and air vent tube (AIR) from the
bracket. (Loosen the nuts on the back of the bracket.)
To turn power off, be sure to turn the main power OFF.
UV Cooling Unit
Syringe
IN(Upper)
AIR(Lower)