Maintenance Manual > Adjustment > Adjustment Items > CAPPING
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver 1.80 / 1.00 Remark
2.0
Rev.
4.2.3 CAPPING
Outline
Adjusts the location for capping and wiper. Adjusted value is saved in the system parameter.
Adjustment procedure
1. Select [#ADJUST] -> [CAPPING].
2. Adjust the capping position.
(1) Be sure to adjust it to the position at which the cap may con-
tact the head.
(2) Turn off the power supply, and check that the carriage does
not move to the table side.
[]/[]: Horizontally shifts the head.
[ENTER]: Finalizes
[END]: End
3. After adjustment, register with the [END] key and then termi-
nate the operation.
FUNCTION
#ADJUST <ent>
#ADJUST
CAPPING <ent>
#CAPPING
CAP POS. = 0.0mm
Cap slider perspective diagram
Minus numeric
direction
Plus numeric
direction
When the excitation of the motor has been cut, the
carriage may move to the table side by itself. At
this time, the cap Assy moves to the bottom, and it
results in capping defect. Therefore, be sure to
check (2) above.
The carriage moves by
itself.
Power OFF
Capping OK
CappingNG
The cap slider moves to the position at
which it goes down, and it results in cap-
ping defect.