Maintenance Manual > Disassembly and Reassembly > Covers > “Tube_FFC Holder” Stick the Protection tape
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
Rev.
6.1.3 “Tube_FFC Holder” Stick the Protection tape
Outline
FFC connected with the slider PCB is fixed with “Tube_FFC Holder” (at two positions). By the screw coming out
from this plate may damage FFC.
To prevent this, or as the countermeasure to prevent it from recurring after a problem occurred, paste protection tape
on this plate.
Procedures
1. Turn the main power OFF
2. Remove the following covers:
Upper Cover
Rear Cover
Slider PCB Cover
Refer to “ 6.1.1 Cover Layout
Explanation of Slider PCB BKT part
3. Remove the Bear Fixing BKT.
Fixing Screw x2
To turn power off, be sure to turn the main power OFF.
Tube_FFC Holder
Lower part of the Slider PCB BKT
On the Bear Guide
Bear Fixing BKT