3.5.1 Replacement of LEDUV Irradiation Assy
List of Replacement Procedures
Item Work operation Description
Ref.
Cooling Water
1.
Drain the cooling water Drain the cooling water of the LED-UV Unit
“#ADJUST EXCHANGE LED UV”
4.2.8
Power OFF
2.
Main power OFF
-
Covers
3.
Removal of the covers Remove the Front Cover, Upper Cover.
6.1.1
LED-UV UNIT
4.
Removal and disassembling of the
LED-UV UNIT
Remove the LED-UV UNIT and disassemble it.
6.7.1
5.
Replacing Assy Replace the LED-UV irradiation Assy.
6.
Assembling of the LED-UV UNIT
and attaching it
Assemble the LED-UV UNIT and attach it.
Covers
7.
Mounting of the covers Mount the covers which have been removed.
6.1.1
Cooling Water
8.
Filling cooling water Fill cooling water of the LED-UV UNIT “Total amount: 450ml”.
-
Power ON
9.
Main power ON
-
Operation
check
10.
Operation checking of the LED- UV
UNIT
Check the operation of the LED - UV UNIT
-