EasyManua.ls Logo

MIMAKI UJF-3042 - 2011 Mimaki Engineering Co.,Ltd

MIMAKI UJF-3042
243 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2011 MIMAKI ENGINEERING CO.,LTD. 6.3.9 R.2.0 P.2
6.3.9 X Gear Box
1
2
3
4
5
6
7
8
9. Remove the FFC from the Station III PCB, and remove the
clamp on the FFC.
10. Remove the 4 screws (P4x10SMW) from the base BKT
11. Remove the 2 screws (CS3x40) from the X-T pulley, and
remove the X-T pulley.
12. Remove the 5 screws (CS3x25) fixing the X gearbox Assy.
13. Lift the X gearbox Assy, and disconnect the relay connector and
encoder connector connected to the X motor.
FFC
Station III PCB
PCB BKT
X-T pulley
Relay connector
Encoder connector
X motor
Maintenance Manual > Disassembly and Reassembly > Driving Parts > X Gear Box
Model UJF-3042/FX Issued 2010.08.27 Revised 2013.07.18 F/W ver --- Remark