7.2.2 Discharging defect cannot be improved by cleaning.
1
2
3
4
5
6
7
8
7. Perform pressure filling of cleaning liquid from the air drain
port.
(1) Uncap the air drain port.
(2) Set the syringe kit with 10cc of cleaning liquid on the air
drain port.
(3) Fill 10cc taking time of 15 to 20 sec.
At this time, check that cleaning liquid shower down from
the nozzle.
(4) Remove the Syringe kit and cap the air drain port.
8. Press [ENTER] key.
9. Perform [MAINTENANCE] - [FILL UP INK] - [air pg].
*To avoid cleaning liquid from mixing with ink.
10. Close the Front cover TB.
11. Attach the Front cover.
12. Perform test drawing to check that there is no blur.
*If there are any blur, perform cleaning.
For this work, the syringe is used, however, do not
pull out the piston when you connect with the air
drain port. It may absorb foreign object into the
nozzle and cause nozzle defect.
While holding the filter with your hand to avoid
the filter from coming off due to the pressure of
the syringe, fill cleaning liquid.
STATION
COMPLETED <ent>
<LOCAL>
FUNCTION
MAINTENANCE <ent>
MAINTENANCE
FILL UP INK <ent>
FILL UP INK
TYPE:air pg