Maintenance Manual > Troubleshooting > Details on Errors and Malfunctions > List of SYSTEM HALT
Model UJF-3042/FX Issued 2010.08.27
Revised
2011.09.30
F/W ver
1.80 / 1.00
Remark
2.0
Rev.
7.1.4 List of SYSTEM HALT
List of SYSTEM HALT (1/7)
No. LCD Cause Corrective Measures
1
SYSTEM HALT (*)
104 : +35V RECVR
35 V Power recovery error 1. Replace the Power Supply PCB with a new one. (Refer
to 6.4.1)
2. Replace the Main PCB with a new one. (Refer to 3.3.1)
2
SYSTEM HALT (*)
10e :FROM CLEAR
F-ROM CLEAR error (F-ROM clear unable)
F-ROM is not clearable on Parameter
writing, FW down loading and Log clearing.
(fls_secclr)
1. Execute the memory check (F-ROM) of [#TEST].
2. Upload the parameter and initialize all parameters with
[#PARAMETER].
3. Replace the Main PCB with a new one. (Refer to 3.3.1)
3
SYSTEM HALT (*)
10f : FROM WRITE
FROM WRITE error (F-ROM writing
unable)
F-ROM is not clearable on Parameter
writing, FW down loading and Log clearing.
(fls_secclr)
1. Execute the memory check (F-ROM) of [#TEST].
2. Upload the parameter and initialize all parameters with
[#PARAMETER].
3. Replace the Main PCB with a new one. (Refer to 3.3.1)
4
SYSTEM HALT (*)
110 : PCB KEY
No Keyboard PCB 1. Check the connections between the Keyboard PCB and
the Main PCB and then disconnect and connect the
FFCs.
2. Replace the FFCs of the above routes.
3. Replace the Keyboard PCB with a new one.
4. Replace the Main PCB with a new one. (Refer to 3.3.1)
5
SYSTEM HALT (*)
114 : PCB PUMP
No Pump III PCB 1. Check the connections between the Pump PCB and the
Main PCB, and then disconnect and connect the FFCs .
2. Replace the FFCs of the above routes.
3. Replace the Pump III PCB with a new one.
(Refer to 6.4.6)
4. Replace the Main PCB with a new one. (Refer to 3.3.1)
5. Replace the SL-Relay PCB with a new one.
(Refer to 3.3.2)
6
SYSTEM HALT (*)
115 : PCB MAIN-F1
Main PCB fuse (F1) disconnected. Replace the Main PCB with a new one. (Refer to 3.3.1)
Before Main PCB replace, do the following checks.
1. Check the connections between the SL-Relay PCB
and the Main PCB, and then disconnect and connect
the FFCs or the like.
2. Check short between 1 pin and 12 pin, and between 3
pin and 12 pin of CN6 of the SL-Relay PCB.
(If shorted out, replace also the SL-Relay PCB.)
3.
Check the connections between the SL-Relay PCB
and the Slider PCB and then disconnect and connect
the FFCs or the like.
4. Check short between 1 pin and 16 pin, and between 3
pin and 16 pin of CN1 of the Slider PCB.
(If shorted out, replace also the Slider PCB.)
7
SYSTEM HALT (*)
116 : PCB MAIN-F2
Main PCB fuse (F2) disconnected.
8
SYSTEM HALT (*)
117 : PCB MAIN-F3
Main PCB fuse (F3) disconnected.
.
9
SYSTEM HALT (*)
12d : PCB MAIN-F4
Main PCB fuse (F4) disconnected.
10
SYSTEM HALT (*)
13e : PCB STATION-F1
Station PCB fuse (F1) disconnected. 1. Replace the Station III PCB with a new one. (Refer to
6.4.4)
11
SYSTEM HALT (*)
13f : PCB STATION-F2
Station PCB fuse (F2) disconnected.
12
SYSTEM HALT (*)
140 : PCB STATION-F3
Station PCB fuse (F3) disconnected.
13
SYSTEM HALT (*)
147 : DS-IC BUSY
DALLAS IC BUSY
error 1. Check connection of the ID Contact PCB connection
cable and damage of the cable.
2. Try to use a different cartridge.
3. Replace the ID Contact PCB Assy. with a new one.
(Refer to 3.3.3)
4. Replace the SL-Relay PCB with a new one.
(Refer to 3.3.2)
14
SYSTEM HALT (*)
159 : PCB SLDR-F1
Slider PCB fuse (F1) disconnected 1. Replace the Slider PCB with a new one. (Refer to
6.4.5)