6.4.5 P.1
1
2
3
4
5
6
7
8
R.1.0
Maintenance Manual > Disassembly and Reassembly > PCBs > Slider PCB
Model
UJF-3042
Issued
2010.04.08
Revised
F/W ver
---
Remark
1.0
Rev.
6.4.5 Slider PCB
Procedures
1. Turn the main power OFF.
2. Remove the following covers:
Upper Cover
Slider PCB Cover
3. Disconnect all connectors on PCB.
4. Remove the Slider PCB Assy..
Screw : P3x8SMW x4
5. Reverse the disassembly procedure for reassembly.
To turn power off, be sure to turn the main power OFF.