Maintenance Manual > Disassembly and Reassembly > Sensors > Cover sensor
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0
Rev.
6.5.4 Cover sensor
Working Procedure
1. Turn the main power off.
2. Remove the Front cover.
3. Take the Micro SW-BKTL off .
4. Take the Sensor off.
Disconnect the connector of the sensor.
Remove two fixing screws.
5. Perform the assembly by reversing the disassembly procedure.
To turn power off, be sure to turn the main power OFF.
Cover sensor
Micro SW-BKTL
Sensor
Connector
Fixing screw