© 2011 MIMAKI ENGINEERING CO.,LTD. 4.2.7 R.2.0 P.1
1
2
3
4
5
6
7
8
Maintenance Manual > Adjustment > Adjustment Items > HEAD TEMP
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver 1.80 / 1.00 Remark
2.0
Rev.
4.2.7 HEAD TEMP
Function
Confirms/sets the head temperature.
Procedure
1. Select [#ADJUST] -> [HEAD TEMP].
2. Enter (confirm) the head temperature.
[]/[]: Changes values.
[ENTER]: Confirms
[END]: Return
Under normal conditions, do not change this.
FUNCTION
#ADJUST <ent>
#ADJUST
HEAD TEMP <ent>
#HEAD TEMP
TEMP = 45° C