© 2011 MIMAKI ENGINEERING CO.,LTD. 6.7.1 R.2.0 P.2
6.7.1 LED UV UNIT
1
2
3
4
5
6
7
8
Procedures
1. Drain the cooling water completely.
Follow the procedure given in
“ 4.2.8 EXCHANGE LED UV “
2. Turn the main power OFF.
3. Remove the following covers:
• Front Cover
• Upper Cover
4. Disconnect the relay connector and the Two Couplers of Cool-
ing Water Tube.
5. Remove the Fixing Screw and take LED UV UNIT off.
6. Evacuate cooling water remaining in the LED-UV UNIT as
much as possible.
By making the removed LED-UV UNIT upside down, evac-
uate cooling water from its piping.
7. Remove the Front Cover and Filter.
• Remove the hand screw.
8. Remove the Top Cover.
• Screw x2
Coupler of Cooling
Water Tube x2
Connecter x2
Fixing Screw
Handle the device carefully not to damage the radiat-
ing surface (the bottom surface).
Maintenance Manual > Disassembly and Reassembly > UV Parts > LED UV UNIT
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver --- Remark
2.0